E44-255 · Valve Selection and Internal Leakage · Globe valve J41H-16 DN80 · ★★
Pressure drop across the valve is 0.18MPa (piping allows ≤0.05MPa); local resistance coefficient ζ=8 (a ball valve only 0.1); pump power use rises 12%
[Mechanism] The globe's S-shaped flow passage has ζ as high as 6-9; at 30m³/h flow, Δp=ζ·ρv²/2=0.18MPa.
[Calculation] A globe valve was misused on a frequently modulated, resistance-sensitive duty, raising energy use.
[Design Omission] Selection ignored flow resistance and modulation frequency, and piping pressure drop was not checked - the globe valve wasted energy.
1) Switch high-flow, low-modulation duties to a gate or ball valve (ζ≤0.5), since the globe's ζ=8 gave Δp=0.18MPa and 12% more pump power, cutting the drop to ≤0.05MPa;
2) On modulating duties use a control valve or a low-resistance streamlined globe, since a streamlined globe can drop ζ to 3, cutting resistance;
3) Check the whole piping pressure drop with margin, since it exceeded the 0.05MPa limit and ran the pump long-term overloaded, stabilizing the system;
4) At high flow, add a parallel tank bypass to relieve valve throttling, since splitting flow lowers per-valve v and Δp∝v² falls, saving power;
5) Select by Cv check, since insufficient Cv forces throttling that raises the drop, holding a 20% Cv margin;
6) Periodically clean internal scaling to lower ζ, since scale narrows the passage and raises ζ, restoring flow capacity;
7) Fit a VFD to the motor to vary speed with flow, since fixed speed wastes power while the valve throttles, matching the load;
8) Put flow resistance into the selection calculation, since the unchecked selection was the root cause of energy waste, closing the loop at design.
GB/T 12235-2007 Steel globe valves and lift check valves for petroleum, petrochemical and related industries