E44-041 · Siphon and Backflow · Vacuum Suction Pipe · ★★
After suction the siphon is not broken, the residual material is drawn in, and the product batches mix
[Continuous Siphon] The level difference maintains the siphon, so material that should not flow is drawn.
[Batch Mixing] The back-suction mixes different batches.
[Design Omission] No vacuum breaker valve at the highest point, so the continuous siphon caused mixing.
1) Break the vacuum at the highest point after suction to stop the siphon, because the level difference maintains the siphon and draws material that should not flow, mixing batches, thereby breaking the vacuum to stop the flow;
2) Provide a vacuum breaker valve that actuates automatically, because automatic vacuum breaking is timely and does not rely on people, thereby reliable;
3) Clean the pipe between batches to prevent residue, because residue causes batch mixing, thereby cleaning the pipe;
4) Install a check valve on the suction pipe to prevent back-suction, because the check valve positively stops back-suction, thereby preventing mixing;
5) Stop the pump automatically when the level reaches zero, because stopping at zero avoids drawing dry, thereby automatic;
6) Slope the piping to aid drainage, because the slope drains it completely with no residue, thereby emptying;
7) Commission and verify there is no batch mixing, because verification confirms it, thereby acceptance;
8) Include vacuum breaking in the batch operation, because the original lack of vacuum breaking is the root cause of batch mixing, thereby the operation must include it.
GB/T 20801-2020 Pressure piping code