E44-589 · Seal Leakage · Pump Wear Ring · ★★
Recirculation, volumetric efficiency 80% and falling
[Mechanism] Wear of the wear ring allows internal recirculation.
[Calculation] The enlarged gap gives 20% recirculation and an efficiency of 80% against 90%.
[Design Omission] The ring was not replaced, the gap was not controlled and nothing was inspected - the ring wore.
1) Change the wear ring (0.3mm gap, wear resistant); the original wear enlarged the ring gap, gave 20% recirculation and an efficiency of 80% against 90%, so controlling the gap restores the efficiency;
2) Control the ring gap at <=0.5mm (select by measurement); a large gap causes recirculation, and controlling the gap prevents it;
3) Verify the impeller concentricity (runout <=0.05); an offset causes wear, and verifying the concentricity prevents it;
4) Select a hard ring (stainless steel or Stellite); a soft ring wears easily, and a hard one prevents it;
5) Filter the incoming liquid to remove sand (inlet strainer); sand causes wear, and filtering it out prevents that;
6) Inspect the volumetric efficiency (performance test); it falls gradually as recirculation develops, so it is checked;
7) Control the shaft axial movement to <=0.1 (bearings); movement causes wear, and limiting it prevents that;
8) Write the ring replacement and the gap control into the maintenance card; the original failure to replace the ring was the root cause of the wear, so the maintenance card closes the loop.
GB/T 13007-2011 Centrifugal Pumps