E44-388 · Water Hammer and Pressure Surge · Single Protection for Whole System · ★★
Protection was installed only at the upstream end; the downstream wave was not cut, and Δp=1.5MPa at the downstream end exceeded the allowable and ruptured it.
[No Zoned Protection] Protection only at the upstream end leaves the downstream wave strong.
[Rupture] Downstream Δp=1.5 exceeds the allowable and ruptures.
[Design Omission] Protection was not zoned along the line and no simulation was run — unzoned protection resulted.
1) Zone protection along the line according to the peak distribution: upstream-only protection left downstream Δp=1.5 exceeding and rupturing; zoning cuts peaks;
2) Use water-hammer simulation to set protection per segment: hidden peaks are hard to detect, so simulation drives the layout;
3) Install a relief valve at the downstream end to limit the peak: the downstream end is weakest, so it is relieved there;
4) Raise pipe ratings per segment to match the peaks: segment allowables were low, so they are raised;
5) Slow-closing check valves lower the source amplitude: a large source makes strong waves, so slow closing is used;
6) Provide overpressure interlock with segmented shutdown: overpressure is hazardous, so zoned interlock is used;
7) Periodically review protection coverage: modifications and extensions create gaps, so review is used;
8) Write zoned protection into the design: the original lack of zoning was the root cause of rupture, so design review enforces it.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection