Knowledge Base › Fluid Systems Error Case › Inconsistent Flow Indication

Inconsistent Flow Indication

E44-748 · Uneven Flow Distribution · Flow indication · ★★

Problem Description

Inconsistent indication, deviation

Root Cause

[Mechanism] Inconsistent readings between the meters make the flow deviate.
[Calculation] The discrepancy makes the flow reading uncertain.
[Design Omission] No calibration, no cross-check, and no inspection were provided, so the indications disagree.

Corrective Solution

1) Calibrate all meters to agree (calibrate each against the same standard, deviation ≤2%), because the original inconsistent indication read a deviation >10%, thereby bringing the meters into agreement;
2) Run a comparison test (compare the meters against each other, difference ≤2%), because doubt means deviation and comparison resolves it, thereby comparing;
3) Standardize the meter model (same type and range), because a difference causes discrepancy and sameness means accuracy, thereby standardizing the type;
4) Monitor the indications (readings of each meter, calibrate on any difference), because gradual drift is invisible and monitoring catches it, thereby giving early warning;
5) Clean the pressure tappings against blockage (clean them at fixed intervals, keep them clear), because blockage causes discrepancy and cleaning restores accuracy, thereby cleaning the tappings;
6) Control the medium parameters (temperature and pressure compensation), because changing conditions cause discrepancy and control steadies them, thereby controlling the parameters;
7) Check the calibration at fixed intervals (quarterly, against a standard), because drift over time causes discrepancy and checking restores accuracy, thereby checking the calibration;
8) Write the meter calibration and comparison into the maintenance card (calibration records), because the missing calibration was the root cause of the disagreement and freezing it into the maintenance card enforces control.

Checklist

Reference

GB/T 2624.1-2006 Flow measurement

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »