E44-390 · Water Hammer and Pressure Surge · Solenoid Valve Second-Level Cycling · ★★
Second-level solenoid-valve cycling produces a large Δv and Δp=1.0MPa exceeding the allowable, vibrating and leaking the downstream pipe.
[Second-Level Closure] Second-level timing changes v abruptly, generating a wave Δp=1.0.
[Leakage] Exceeding the allowable, vibration and leakage occur.
[Design Omission] No slow actuation and no damping were provided — second-level closure hammer resulted.
1) Convert the solenoid to a slow-acting type or add throttling damping: second-level timing made Δp=1.0 exceed and leak; slow actuation lowers the change;
2) Provide a bypass to slowly open the main valve: direct closure generates waves, so a slow bypass is used;
3) Check cycling Δp ≤ allowable: the original lack of calculation caused leakage, so accurate calculation is used;
4) Install an arrester downstream to cut the peak: the wave amplitude exceeds the limit, so it absorbs the peak;
5) Up-rate the pipe or use a metal gasket: a low allowable caused leakage, so the rating is raised;
6) Limit the cycling rate: fast action causes hammer, so the rate is limited;
7) Recheck by water-hammer simulation, because estimates fall short; hence simulation;
8) Write slow actuation into valve selection: the original second-level closure was the root cause, so selection review enforces it.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection