Backflow Causing Reverse Suction at the Outlet

E44-944 · Siphon and Backflow · Outlet · ★★

Problem Description

Backflow, reverse suction, disorder

Root Cause

[Mechanism] The outlet pipe elevation is lower than the upstream liquid level, so on pump stop or a reversal of differential pressure the upstream liquid is sucked back to the pump side through the outlet, disrupting the flow direction.
[Calculation] With an inside-outside difference of 1.4 m the reverse suction is v≈0.6 m/s and 0.04 m³/h, and the outlet can no longer discharge normally.
[Design Omission] No isolation, no elevation-difference check, and no vacuum breaking or fast shutoff.

Corrective Solution

1) Install a slow-closing check valve at the outlet (seepage ≤5 mL/min), because reverse suction enters through the outlet and the check valve cuts off the source and preserves the direction, thereby isolating it against reverse suction;
2) Check the outlet elevation so it is 0.3 m above the upstream liquid level (originally 1.4 m lower), because a positive difference eliminates the reverse driving force and the layout prevents suction, thereby preventing reverse suction by elevation;
3) Link the pump stop to the vacuum break valve (open on pump stop to break the siphon), because backflow tends to occur after pump stop and the linkage breaks it at once, thereby isolating it actively;
4) Upgrade the outlet flanges to PN16 with airtightness (0.6 MPa), because slight leakage causes slow suction and improved sealing stops the seepage, thereby preventing seepage-driven reverse suction;
5) Perform a reverse suction test (open the outlet and verify no back-suction), because the design omitted the height check and the test confirms the isolation effect, thereby verifying the isolation;
6) Provide a reverse flow meter with an alarm (alarm on reverse flow), because reverse suction first shows as reverse flow and is cut off early, thereby monitoring the flow direction to prevent disorder;
7) Control the operating difference ≥0.3 m with an alarm (adjust if lower), because keeping a positive difference prevents reverse suction and controlling it prevents disorder, thereby preventing backflow in operation;
8) Write the check valve and elevation-difference checking into the outlet regulations, because the root cause of reverse suction is a reversed difference without isolation, so the regulations must govern to prevent disorder.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »