Valve Pressure Rating Too Low for the Service

E44-1035 · Valve Selection & Internal Leakage · Valve · ★★

Problem Symptom

Rating too low, leakage, rupture

Root Cause

[Mechanism] The valve pressure class PN is below the maximum operating pressure of the line, so the flanges and the valve body leak or rupture under overpressure.
[Calculation] The operating peak pressure was 2.6MPa but PN16 (2.5MPa class, about 2.0MPa permissible after the temperature derating) was selected, 30% below the service; the flange bolt stress exceeded the allowable value by 25%.
[Design Omission] The maximum operating pressure was never verified, the pressure class was not selected properly, and no strength check was made.

Correct Solution

1) Change to a PN25 valve (2.5MPa x temperature derating still covers 2.6MPa); the original PN16 was below the operating peak pressure and raising the class secures it, making the pressure rating compliant;
2) Verify that the valve pressure class is >=1.1 x the operating peak pressure (originally not checked); selecting a low class causes rupture and verifying the class secures it, making the selection compliant;
3) Change to high-strength flanges (PN25 matched pair); a mismatched flange/valve leaks and changing them makes the pairing correct, sealing the flange joint;
4) Add a safety valve (set to lift at 2.6MPa); overpressure shows up first as a pressure rise and early relief prevents rupture;
5) Carry out a shell strength test (1.5 x PN hold pressure); the class was wrongly selected and never verified, and measurement confirms no rupture, so the data fixes the strength;
6) Fit a pressure transmitter and alarm (report above 2.6MPa); overpressure shows up first as a pressure change and early detection gives warning, monitoring the pressure;
7) Control the operating pressure at <=2.4MPa (reduce the rate above that); exceeding PN makes the stress large and controlling the pressure prevents rupture, preventing leakage in operation;
8) Write the pressure verification and class selection into the specification; the root cause of the low rating was a missing operating-peak check with no proper class selection, so the specification closes the loop.