E44-403 · Two-Phase Flow and Air Binding · Centrifugal Pump with Gas Trapped in Suction Line · ★★★
Trapped gas in the suction line made the pump lose prime; flow dropped 60%, cavitation noise was prominent, and the shaft seal ran hot.
[Air Binding] Suction-side gas occupies the section, starving the inlet and leaving gas in the pump chamber.
[Loss of Prime] Gas keeps the impeller from lifting liquid; flow drops 60%.
[Design Omission] No suction vent and no inducer — suction-side air binding.
1) Slope the suction line toward the pump and vent the high point; trapped gas caused loss of prime, a 60% flow drop and cavitation, so vent and keep the line full;
2) Fit an inducer at the suction to break up gas pockets; pockets block the suction, so the inducer disperses them;
3) Check NPSHa against cavitation; gas lowers the available NPSH, so verify NPSH;
4) Provide a suction straight run ≥5D to steady the flow; vortexing draws in gas, so keep the flow steady;
5) Add a suction vacuum breaker to prevent dry running; dry running draws in gas, so break the vacuum;
6) Install a separator upstream of the pump; gas-laden flow damages it, so separate first;
7) Vent and check for trapped gas periodically; buildup is gradual and easy to miss, so vent and inspect;
8) Write suction venting into the design; trapped gas was the root cause of binding, so close the loop at design.
GB/T 5657-2013 Technical specifications for centrifugal pumps