E44-012 · Seal Leakage · Pipe Flange · ★★

Problem Description

The asbestos-rubber gasket aged and cracked at 350℃ steam; the flange leaked 0.5m³/h, with bolts retightened six times a month.

Root Cause

[Gasket Temperature Rating] The asbestos gasket is rated <300℃; at 350℃ it creeps and relaxes, dropping the seating stress to 12MPa < the required 20.
[Creep] At high temperature the gasket creeps, dropping the bolt load 30% and leaving insufficient seating pressure.
[Design Omission] No spiral-wound or serrated metal gasket was chosen and flange stiffness was uncontrolled — the aged gasket leaked.

Corrective Solution

1) For 350℃ steam switch to a spiral-wound or serrated metal gasket; the asbestos gasket rated <300℃ creeps and relaxes, dropping seating stress to 12 <20, so a metal gasket holds the seal at temperature;
2) Check flange stiffness and control deflection ≤0.2mm; flange flexing locally opens a gap and leaks, so keep the flange rigidly seated;
3) Size the bolt torque from the gasket seating stress and tighten diagonally; uneven load makes local seating pressure <20, so spread it to the design preload;
4) Widen the gasket modestly to lower unit pressure; a wider gasket has lower unit pressure at the same bolt load and resists crushing, extending life;
5) Machine the flange face to Ra3.2 tooling for full contact; a rough face has micro-gaps that leak, so make a smooth continuous seal;
6) Retorque hot on high-temperature flanges; after warm-up the bolt load drops another 30%, so add hot retightening to hold seating pressure;
7) Pressure-test for no seepage; leakage is the direct sign of seal failure, so make it acceptance;
8) Write the gasket selection into the piping material list; the wrong asbestos gasket was the leak cause, so gate the material.

Checklist

Reference

GB/T 4622.3-2007 Spiral wound gaskets - Specifications