E44-291 · Valve Selection and Internal Leakage · DC solenoid valve 4V210-08 DC24V · ★★
Reversed power polarity left the coil with no correct magnetic field; the spool would not move and the system did not respond. It was misread as a bad valve and three were replaced.
[Polarity] Reversing a DC coil reverses the current direction and the magnetism, so it does not pull in.
[Misjudgment] It looked like a dead valve, so three were replaced in a row.
[Design Omission] No polarity marking and no voltage-direction check — the solenoid would not act.
1) Mark positive/negative per the nameplate and check the voltage direction; reversed connection made the magnetism wrong, the spool stayed put, and three valves were wrongly swapped, so get the polarity right;
2) Add a reverse-protection diode or bridge rectifier; reversal is then harmless, so protect against reversal;
3) Measure polarity with a multimeter before energizing; blind wiring easily reverses it, so measure first;
4) Mark the body with a prominent color ring for polarity; without marking it is easy to err, so make it explicit;
5) Add polarity detection and alarm in the control system; reversal is hard to notice, so alarm;
6) Train wiring to the drawing; people err, so wire to the drawing;
7) Choose an AC solenoid to avoid polarity; AC has no polarity, so remove the concern;
8) Bring polarity verification into the wiring card; the missing mark was the cause of reversal, so gate wiring.
GB/T 30493-2014 Industrial process control valves - Part 8