VFD lower speed limit set too low causes recirculation cavitation

E44-242 · Pump Selection & Cavitation · VFD driven booster pump IS100-80-160 · ★★★

Problem Symptom

The VFD was turned down to 25Hz (the lower limit should be ≥35Hz); at the low speed the head was insufficient, the flow collapsed to 0.3Q and inlet recirculation cavitation set in

Root Cause

[Cavitation] A VFD lower limit that is too low drives the flow below the minimum continuous stable flow and causes inlet recirculation cavitation.
[Calculation] As n falls H falls with n²; at 25Hz the head drops to 0.25 of its value and the operating flow falls to 0.3Q against Qmin, so the low pressure caused by inlet recirculation cavitates.
[Design Omission] The VFD lower limit was not set with the minimum flow constraint, so the pump was allowed to run into recirculation.

Correct Solution

1) Set the VFD lower limit to ≥35Hz so that Q≥Qmin, because below that limit the pump recirculates and cavitates, thereby keeping the machine out of the recirculation region;
2) Back-calculate the allowable minimum frequency from the minimum flow, because the frequency limit follows from Qmin, thereby setting the correct lower bound;
3) Fit a recirculation valve to maintain the minimum flow, because the flow is small at low frequency, thereby making up the shortfall;
4) Set a hard lower frequency limit in the VFD, because an operator can accidentally adjust it too low, thereby preventing the limit from being exceeded;
5) Add a low-flow alarm interlock, because the condition is otherwise hidden, thereby giving early warning;
6) Select an impeller with improved inlet recirculation tolerance, because the structure is improved, thereby easing the problem;
7) Test at the minimum frequency during commissioning to confirm there is no recirculation cavitation, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate the VFD lower limit constraint into the design, because the original value was the root cause, so the design must include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH