E44-281 · Valve Selection and Internal Leakage · Single-seat control valve PN40 DN50 · ★★★
Downstream of the trim at high pressure drop, cavitation pits reached 1mm deep, the flow characteristic distorted, and internal leakage was 1L/min.
[Cavitation] Δp/p1=0.6 exceeds the critical value, dropping throat p < vapor pressure; bubbles collapse and erode the trim.
[Distortion] Erosion changes the profile and drifts Cv.
[Design Omission] The pressure drop was not split and no erosion-resistant trim was used — the control valve eroded.
1) Limit Δp/p1≤0.3 to split the pressure drop; 0.6 is supercritical and drops p < vapor pressure with 1mm pitting, so control the drop to avoid erosion;
2) Switch to a multi-stage pressure-reduction cage trim; a single large drop erodes and distorts the profile, so step it down and stabilize;
3) Hardface the trim with cemented carbide against erosion; the original material eroded and drifted Cv, so make it erosion-resistant;
4) Add an anti-cavitation diffuser downstream; the vena contracta scours hard, so diffuse;
5) Periodically measure Cv drift to detect erosion; erosion causes drift, so diagnose early;
6) Degas the medium first when it carries gas; gas promotes erosion, so clean the flow;
7) Select a low-noise, erosion-resistant valve type; erosion comes with noise, so optimize the form;
8) Include the pressure-drop ratio in selection; the lack of control was the cause of erosion, so gate it at design.
GB/T 4213-2008 Pneumatic industrial-process control valves