E44-078 · Uneven Flow Distribution · Gas distribution header · ★★
The friction pressure drop along the header makes the branch static pressures differ, the flow ratio 40:30:30 is out of balance, and the reactor distribution is uneven
[Static-Pressure Difference] The friction pressure drop along the header raises the static pressure of the near-end branches and they fight for flow.
[Calculation] The friction pressure drop creates a pressure difference between the branches, giving a flow ratio of 40:30:30.
[Design Omission] Neither a header pressure drop below 5% nor balancing orifices were provided, so the system is out of balance.
1) Keep the friction pressure drop along the header below 5%, because the friction drop raises the static pressure of the near-end branches and they fight for flow, while a small drop equalizes the branch static pressures, thereby evening the flow ratio;
2) Fit balancing orifices on the branches (sized to the resistance split), because the orifices deliberately add resistance at the far end and balance the branches, thereby bringing the flow ratio back to even;
3) Lay out symmetrically to reduce flow deviation, because an asymmetric header lowers the far-end pressure and symmetry evens it, thereby eliminating the deviation;
4) Fit flowmeters on the branches, because the imbalance must be quantified and monitoring locates which branch deviates, thereby guiding the adjustment;
5) Validate with flow-field simulation, because the gas is compressible and simulation predicts the split, thereby enforcing design control;
6) Verify at commissioning that the flow ratio matches the design distribution, because uneven reactor distribution varies the reaction and must be measured, thereby performing acceptance;
7) Fine-tune the orifices locally, because some branches still deviate and orifice adjustment compensates, thereby refining the distribution;
8) Make the header design a mandatory process item, because the original failure to control the pressure drop caused the imbalance, thereby distributing the flow evenly already at the process stage.
GB/T 20801-2020 Pressure piping code