E44-735 · Uneven Flow Distribution · Manifold · ★★
Uneven pressure drop, flow deviation
[Mechanism] An uneven pressure drop deviates the flow.
[Calculation] A difference in pressure drop causes the deviation.
[Design Omission] No pressure-drop balancing, no verification, and no inspection were provided, so the pressure drops differ.
1) Balance the pressure drop of each branch (adjust until the Δp difference between branches is ≤2%), because the original pressure-drop difference made the flow deviate by >15%, thereby balancing the drop and evening the flow;
2) Verify the manifold pressure drop (calculate each branch, difference ≤3%), because a difference causes deviation and verification evens it, thereby verifying the drop;
3) Provide restriction orifices (sized to the flow, β0.5), because fighting for flow causes deviation and restriction splits it, thereby restricting the flow;
4) Increase the manifold diameter (keep the far-end drop ≤5% of the total), because a small diameter makes the drop difference large and a larger diameter eases it, thereby increasing the diameter;
5) Monitor the flow deviation (a meter on each branch, alarm above 5%), because gradual deviation is invisible and monitoring catches it, thereby giving early warning;
6) Steady the total pressure (steady pump, fluctuation ≤2%), because changing conditions cause deviation and control steadies them, thereby steadying the pressure;
7) Run a flow test (measure each branch, accept when even), because the lack of testing caused the deviation and testing verifies it, thereby testing the flow;
8) Write the drop balancing and verification into the calculation sheet (pressure-drop table for each branch), because the missing balancing was the root cause and freezing it into the calculation sheet enforces control.
GB/T 20801.3-2020 Design code for industrial metallic piping