Knowledge Base › Fluid Systems Error Case › Uneven Pressure Drop in a Manifold

Uneven Pressure Drop in a Manifold

E44-735 · Uneven Flow Distribution · Manifold · ★★

Problem Description

Uneven pressure drop, flow deviation

Root Cause

[Mechanism] An uneven pressure drop deviates the flow.
[Calculation] A difference in pressure drop causes the deviation.
[Design Omission] No pressure-drop balancing, no verification, and no inspection were provided, so the pressure drops differ.

Corrective Solution

1) Balance the pressure drop of each branch (adjust until the Δp difference between branches is ≤2%), because the original pressure-drop difference made the flow deviate by >15%, thereby balancing the drop and evening the flow;
2) Verify the manifold pressure drop (calculate each branch, difference ≤3%), because a difference causes deviation and verification evens it, thereby verifying the drop;
3) Provide restriction orifices (sized to the flow, β0.5), because fighting for flow causes deviation and restriction splits it, thereby restricting the flow;
4) Increase the manifold diameter (keep the far-end drop ≤5% of the total), because a small diameter makes the drop difference large and a larger diameter eases it, thereby increasing the diameter;
5) Monitor the flow deviation (a meter on each branch, alarm above 5%), because gradual deviation is invisible and monitoring catches it, thereby giving early warning;
6) Steady the total pressure (steady pump, fluctuation ≤2%), because changing conditions cause deviation and control steadies them, thereby steadying the pressure;
7) Run a flow test (measure each branch, accept when even), because the lack of testing caused the deviation and testing verifies it, thereby testing the flow;
8) Write the drop balancing and verification into the calculation sheet (pressure-drop table for each branch), because the missing balancing was the root cause and freezing it into the calculation sheet enforces control.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »