Knowledge Base › Fluid Systems Error Case › Liquid-Phase Vaporization Making the Level Read Falsely Low

Liquid-Phase Vaporization Making the Level Read Falsely Low

E44-631 · Level Control Failure · Liquid-phase vaporization · ★★

Problem Description

Vaporization, reading low, density drop

Root Cause

[Mechanism] Liquid-phase vaporization drops the density.
[Calculation] Vaporization makes the reading falsely low.
[Design Omission] The temperature was not lowered, the density was not stabilized and no compensation was added — so it vaporized.

Corrective Solution

1) Cool it against vaporization (liquid temperature controlled to ≤ boiling point -10℃): because the original local vaporization of the liquid phase (about 2% vaporization) dropped the density and made the differential-pressure reading falsely low by 0.15m, cooling suppresses boiling so the density returns to true and the reading recovers;
2) Raise the back pressure against boiling (tank top pressure ≥ saturation vapor pressure +0.05MPa): because low pressure (<0.1MPa) boils it and raising the pressure suppresses it, vaporization is prevented;
3) Choose a density-compensation algorithm (correct ρ by temperature and pressure): because a change in ρ makes it read low and compensation corrects it, the falsely low reading is reduced;
4) Add insulation against cold-spot boiling (insulation 50mm thick): because a cold spot boils it locally and insulation evens it, the density is steady;
5) Calibrate the density parameter (enter the measured ρ): because a deviation makes it read low and calibrating the density corrects it, it is confirmed;
6) Check for vaporization (inspect for bubbles weekly): because gradual vaporization increases the low reading and checking gives early warning, the temperature is lowered in time;
7) Control the boiling-point margin (operating temperature ≤20℃ from the boiling point): because being close vaporizes it and keeping a margin protects, vaporization is prevented;
8) Write the cooling and pressure raising into the specification: the original lack of cooling was the root cause of the vaporization, so the spec locks it in and specification governs it.

Checklist

Reference

GB/T 17614.1-2008 Transmitters for use in industrial-process control systems