E44-533 · Heat Exchanger Fouling and Insufficient Heat Exchange · Plate-Type Mold Temperature Controller · ★★
Thermal-oil / water scale, reduced K, uneven mold temperature, defective castings
[Mechanism] Process-medium deposits adhere to the plates.
[Calculation] Rf=0.3 lowers K by 30%, creates mold-temperature spread of ±10℃, and causes defective parts.
[Design Omission] No cleaning and no filtration, so fouling occurred.
1) Filter the process medium (accuracy ≤25μm) and clean on schedule (flush every 2000h); because impurities and oil-cracking products adhere to plates, Rf=0.3 lowers K by 30%, and the ±10℃ mold-temperature spread causes misruns / shrinkage cavities, filtering plus cleaning restores K and stabilizes mold temperature;
2) Control temperature to prevent cracking (oil temperature ≤ allowable upper limit, wall temperature below the decomposition point); because high temperature cracks the medium into coke that adheres to plates, temperature control suppresses deposition;
3) Monitor mold temperature (alarm at mold-temperature spread >±5℃); because fouling lowers K first as uneven mold temperature, well before defective parts appear, monitoring gives early warning;
4) Raise flow velocity (≥1.2m/s) to prevent settling; because deposits settle in low-velocity zones, higher velocity reduces residence time and suppresses settling;
5) Use scale inhibitors (thermal-oil antioxidant / water dispersant); because oxides adhere and the inhibitor suppresses adhesion, fouling is inhibited;
6) Use wide-gap plate patterns (corrugated plate gap ≥3mm); because narrow gaps trap scale and cannot be cleaned thoroughly, wide gaps ease flushing;
7) Inspect fouling thickness on schedule (quarterly disassembly check / thickness measurement); because deposits thicken and worsen K loss and mold-temperature spread, quantifying it guides cleaning;
8) Write filtration and cleaning into the mold temperature controller procedure; because the original design omitted filtration and cleaning, the root cause of fouling, the procedure closes the loop.
GB/T 151-2014 Heat exchangers