Knowledge Base › Fluid Systems Error Case › Level Error at a Two-Phase Interface

Level Error at a Two-Phase Interface

E44-639 · Level Control Failure · Two-phase interface · ★★

Problem Description

Interface error, mixing

Root Cause

[Mechanism] An unclear interface causes the error.
[Calculation] Mixing causes the error.
[Design Omission] The phases were not separated, the wrong instrument was chosen and no calibration was done — so it erred.

Corrective Solution

1) Select an interface instrument (RF admittance or a servo interface probe): because the original single-parameter level gauge cannot distinguish the oil-water interface (dielectric difference Δεr=20) and misreads it, and an interface instrument separates the phases by dielectric constant, the interface is measured accurately;
2) Promote separation of the two phases (reduce the mixing intensity, residence time ≥30min): because mixing causes the error and separation clarifies it, the interface is clear;
3) Calibrate the interface zero (calibrate at a known interface): because a deviation causes the error and calibration corrects it, it is confirmed;
4) Control the mixing level (stirrer speed ≤ critical): because mixing causes the error and controlling the mixing promotes separation, the interface is steady;
5) Sample to verify the interface (sample hourly and measure the water content): because doubt leads to error and sampling verifies, it is cross-checked;
6) Check for error (compare daily): because gradual error increases the offset and checking gives early warning, calibration is timely;
7) Allow settling time (settle 30min after filling before measuring): because rushing mixes it and settling clarifies it, the measurement is accurate;
8) Write the instrument selection and phase separation into the specification: the original lack of selection was the root cause of the error, so the spec locks it in and specification governs it.

Checklist

Reference

GB/T 25922-2010 Level meters