E44-276 · Valve Selection and Internal Leakage · Wafer butterfly check valve H76H-16 DN200 · ★★
Two mounting bolts snapped; the flange went skewed, the body bent and jammed on stroking, with 3 failures a month.
[Over-Tightening] Excess torque drove the bolt stress above tensile strength σ_b and snapped them.
[Skew] Tightening from one side bent the body and misaligned its center.
[Design Omission] No diagonal tightening and no torque control — the check valve's bolts broke.
1) Tighten in a diagonal sequence in stages while controlling torque; over-tightening past σ_b snapped two bolts and skewed the flange, so even out the force;
2) Upgrade the bolt strength grade (8.8→10.9) for margin; the original grade had little reserve and broke easily, so step it up;
3) Add dowel pins to keep the body from skewing; skew bends and jams it, so align it;
4) Check flange-face parallelism; non-parallel loading stresses one side, so true it up;
5) Use a torque wrench for a set torque; feel-based tightening overshoots, so torque to spec;
6) Periodically check bolt loosening and retorque; vibration loosens and re-breaks them, so re-tighten;
7) For large sizes switch to a double-flanged valve to cut installation stress; wafer types skew easily, so mount it stably;
8) Write the tightening procedure into the assembly card; the lack of control was the cause of breakage, so gate assembly.
GB/T 12236-2018 Steel swing check valves for petrochemical industry