E44-1106 · Other · Process Pipe · ★★
Vibration, cracking, leakage.
[Mechanism] Process-pipe supports were sparse and did not avoid the pump excitation frequency; long-term vibration caused fatigue cracks and leakage.
[Calculation] Pump speed 2950rpm=49Hz; pipe natural f_n=50Hz near resonance; stress amplitude σ_a=35MPa>fatigue limit 30MPa; cracked in 3 months.
[Design Omission] No added supports, no frequency avoidance, no span check, and no vibration test.
1) Add supports to avoid vibration (change span ≤2.5m); vibration cracks, and support stabilizes it, restoring stability;
2) Control velocity (cut pulsation); high velocity vibrates, and steady velocity quiets it, suppressing vibration;
3) Check span (dense supports); a large span vibrates, and a small spacing fixes the pipe, stabilizing it;
4) Avoid resonance (move a support to shift f_n); resonance cracks, and frequency avoidance protects, preventing cracking;
5) Run a vibration test (amplitude ≤0.15mm, avoid resonance); untested means unknown, and measured stability confirms it;
6) Install vibration monitoring (alarm on over-limit); a crack first shows as vibration, and early warning catches it;
7) Add damping (absorb vibration); vibration cracks, and damping cuts it, preventing cracking;
8) Record support and frequency avoidance on the process-pipe drawing; the root cause of cracking was no support and near-resonance, so the drawing must gate it.
GB/T 20801.3-2020 Industrial piping