E44-672 · Hydraulic System Contamination and Stick-Slip · Hydraulic System · ★★
Cavitation, noise, air ingress
[Mechanism] Air enters and causes cavitation erosion.
[Calculation] Air causes cavitation and noise.
[Design Omission] No venting, no sealing, and no inspection were provided, leaving air.
1) Tighten pipe fittings against air intake (torque per specification, with anaerobic sealant); because the fittings were slightly loose and sucked air into the pump under negative pressure, causing cavitation noise >85 dB, tight fittings block air;
2) Add high-point vent valves (manual/auto, vented every shift); because trapped gas accumulates at high points and venting clears it, venting prevents cavitation;
3) Keep oil level ≥2/3 of tank height to prevent cavitation (level gauge plus interlock); because low level draws a vortex that sucks in air, controlling the level prevents it and stabilizes the oil level;
4) Raise the suction inlet to prevent vortices (inlet ≥2D above the bottom, with a flow hood); because vortices entrain air into the pump, raising the inlet blocks air;
5) Choose anti-foam hydraulic oil (foaming ≤50 ml, defoaming ≤5 min); because foam entering the system causes cavitation and anti-foam oil suppresses it, this reduces air;
6) Monitor cavitation sound (acoustic emission, alarm >80 dB); because erosion progresses invisibly and acoustic monitoring detects it, this gives early inspection;
7) Seal the pump shaft seal against air intake (replace mechanical seals on leakage); because a leaking shaft seal draws in air and sealing blocks it, this excludes air;
8) Write fitting tightening and venting into the maintenance card (venting every shift); because the original loose fittings are the root cause of air and fixing it closes the loop, maintenance enforces control.
GB/T 3766-2015 General technical conditions for hydraulic systems