Knowledge Base › Fluid Systems Error Case › Noise from Siphon Flow Stoppage

Noise from Siphon Flow Stoppage

E44-937 · Siphon and Backflow · Siphon Pipe · ★★

Problem Description

Flow stoppage, noise, vibration

Root Cause

[Mechanism] The siphon flow regime is unstable, and the movement of the gas-liquid segment generates noise and vibration.
[Calculation] The gas-liquid segment moves at 3 Hz, exciting 85 dB(A) of pipe noise that exceeds the 85 dB workplace limit; the amplitude is 0.3 mm.
[Design Omission] No flow stabilization, no noise attenuation, and no velocity control.

Corrective Solution

1) Add a surge tank plus a buffer tank at the inlet (to smooth flow pulsation), because the moving gas-liquid segment is the noise source and steady flow reduces the noise, thereby removing the noise source;
2) Wrap the pipe sections with a damping layer (insertion loss ≥10 dB(A)), because damping absorbs sound and shaves the noise peak down to 75 dB, thereby reducing noise;
3) Control the flow velocity at 1.2~1.5 m/s to stabilize the flow, because velocity fluctuation excites noise and steady flow reduces vibration, thereby controlling the velocity and suppressing noise;
4) Vent the air at the high points (the gas-liquid segment is the noise source), because removing the air steadies the flow and lowers the noise, thereby suppressing the vibration source;
5) Perform a noise test (measure ≤85 dB(A)), because the design omitted stabilization and the test confirms the noise level, thereby determining the noise reduction from data;
6) Add dampers to the supports (limit the amplitude to <0.1 mm), because vibration transmits noise and damping suppresses it, thereby suppressing vibration and reducing noise;
7) Control the outlet control valve in a closed flow loop (PID), because steady flow means steady noise and the closed loop stabilizes it, thereby controlling the flow and quieting the system;
8) Write flow stabilization and noise attenuation into the design regulations, because the root cause of the flow-stoppage noise is unstable flow without attenuation, so the regulations must govern to reduce noise.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping