E44-172 · Heat-Exchanger Fouling and Insufficient Heat Transfer · Shell-Side Heat Exchanger · ★★
Too few baffles leave shell-side velocity at 0.2m/s (too low); dead zones foul and heat transfer drops 25%.
[Low Velocity] Too few baffles leave v=0.2m/s.
[Dead-Zone Fouling] Deposition occurs in low-velocity dead zones.
[Design Omission] Shell-side velocity was not verified and baffle spacing was too wide, leading to fouling.
1) Space baffles for shell-side velocity ≥0.3m/s, since too few baffles left v=0.2m/s with dead-zone fouling dropping heat transfer 25%, thus densifying them to raise v;
2) Fit a shell-side flow distributor to reduce dead zones, since deposition occurs in dead zones, thus guiding flow to reduce them;
3) Size heat-transfer area including a fouling margin, since fouling lowers K, thus leaving margin;
4) Monitor pressure drop to detect clogging/fouling, since scale adds resistance, thus monitoring resistance;
5) Periodically clean the shell side, since buildup worsens, thus cleaning on schedule;
6) Treat water to prevent scale, since hard water scales faster, thus treating it;
7) Measure heat transfer ≥ design on test run, since design requires verification, thus confirming delivery;
8) Bring shell-side velocity checking into design, since the original lack of checking was the root cause of low velocity, so design must include it.
GB/T 151-2014 Heat exchangers