Knowledge Base › Fluid Systems Error Case › Pump Suction Air Leakage Oil Gas Content Pressure Pulsation

Pump Suction Air Leakage Oil Gas Content Pressure Pulsation

E44-075 · Hydraulic System Contamination and Stick-Slip · Hydraulic Pump Suction Line · ★★

Problem Description

Air leakage in the suction line makes the oil gas fraction >4%; pump outlet pressure pulsates ±15% with noticeable noise

Root Cause

[Cavitation Noise] Air leakage makes the oil gas-bearing, increasing compressibility and pressure pulsation.
[Calculation] Gas fraction >4% makes volumetric efficiency and pressure pulsation exceed ±15%.
[Design Omission] No suction-line air-tightness test and no vent were provided, causing gas-induced noise.

Corrective Solution

1) Perform an air-tightness test on the suction line (hold pressure under vacuum); because leakage occurs in the negative-pressure suction section and the air test finds the leak point, this eliminates the air ingress source and lowers gas fraction;
2) Add a high-point vent valve to release accumulated gas; because micro-leaks admit air and the vent valve discharges on schedule so gas fraction does not accumulate, this maintains low gas content;
3) Control suction flow velocity to prevent vortexing and air ingestion (v<1 m/s); because high velocity causes surface vortices that draw in air and velocity control prevents vortexing, this reduces gas content;
4) Install anti-vortex baffles in the tank; because baffles break the vortex and stop air from being drawn into the suction pipe, this further lowers gas content;
5) Measure gas fraction online (ultrasonic method); because gas>4% causes pulsation and needs quantification, data guides venting;
6) Add negative-pressure protection at the pump inlet (stop pump when too low); because severe air ingestion causes cavitation and the protection prevents damage, this protects the pump;
7) Test-run to verify pressure pulsation≤±5%; because ±15% pulsation indicates gas content and needs direct measurement, this accepts the result;
8) Make air-tightness a mandatory installation-spec item; because the suction section was installed without an air-tightness test, causing gas noise, this is controlled at the installation stage.

Checklist

Reference

GB/T 3766-2015 Hydraulic fluid power - General technical conditions