Problem Description

The cable inside the drag chain twists with vibration; the conductor fatigues and fractures from torsion, causing signal loss

Root Cause

[Mechanism] Torsion of the drag chain puts the cable under torsional stress; the stranded conductor and shield fatigue and break the core, losing the signal.
[Calculation] Torsion drives the conductor stress beyond the fatigue limit, and the core breaks after cycling, making the signal intermittent.
[Design Deficiency] The cable inside the drag chain had no anti-twist fixing.

Corrective Solution

① Anti-twist fixing: add an anti-twist clamp at the cable end → prevent rotation
② High-flex torsion resistance: choose a torsion-resistant, high-flex cable → extend service life
③ Layered routing: separate layers inside the drag chain → reduce twisting
④ Bend slack: leave slack → reduce stress
⑤ Core-fracture monitoring: monitor signal packet loss → early detection
⑥ Torsion check: inspect the torsion state on patrol → early correction
⑦ Torsional-fracture verification: confirm with a torsional fatigue test → data confirmation
⑧ Selection standardization: write anti-twist fixing into the spec → control at the source

Checklist

Reference

GB/T 5013.1-2008 Rubber insulated cables of rated voltages 450-750 V