E45-462 · Vibration and Mechanical Stress · Proximity Sensor · ★★

Problem Description

Vibration makes the nut embedded in the plastic housing rotate and come loose; the sensor mounting fails and it falls off

Root Cause

[Mechanism] Vibration subjects the embedded nut to alternating torque that turns it out; the plastic embedment fails and the mounting loosens.
[Calculation] Vibration loosens the embedded nut and the preload is lost, making the sensor fall off.
[Design Deficiency] The embedded nut had no anti-rotation feature.

Corrective Solution

① Anti-rotation feature: add anti-rotation ribs to the embedded nut → prevent rotation
② Metal insert: switch to a metal insert to improve fixing → strong anchorage
③ Threadlocker: apply adhesive to the screw to secure the insert → prevent loosening
④ Torque compliance: tighten to spec → maintain fixing
⑤ Regular inspection: inspect nut condition on patrol → early correction
⑥ Retaining chain: add an anti-drop chain → prevent loss
⑦ Loosening verification: confirm by measuring rotation under vibration → data confirmation
⑧ Selection standardization: write insert anti-rotation into the assembly spec → control at the source

Checklist

Reference

GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test