Knowledge Base › Electrical Sensor Error Case › Vibration-Induced Fatigue Fracture of the Alarm Bracket

Vibration-Induced Fatigue Fracture of the Alarm Bracket

E45-464 · Vibration and Mechanical Stress · Audible-Visual Alarm · ★★

Problem Description

Vibration fatigues and fractures the mounting bracket of the audible-visual alarm; the alarm falls and fails

Root Cause

[Mechanism] Under alternating vibration stress, fatigue cracks in the bracket propagate until it fractures; the alarm loses support and falls.
[Calculation] The bracket stress exceeds the fatigue limit, and the crack propagates to fracture after several months of operation.
[Design Deficiency] The bracket lacked stiffness and had no fatigue check.

Corrective Solution

① Increase stiffness: thicken the bracket to raise strength → resist fracture
② Fatigue check: verify the life against the S-N curve → ensure safety
③ Damped mounting: add vibration damping to the alarm → reduce stress
④ Damping suppression: add damping to lower Q → reduce the peak
⑤ Flaw detection: check for cracks periodically → early detection
⑥ Redundant fixing: a second bracket as a back-up → prevent falling
⑦ Fatigue verification: confirm with a vibration endurance test → data confirmation
⑧ Selection standardization: write the bracket strength into the spec → control at the source

Checklist

Reference

GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test