Knowledge Base › Electrical Sensor Error Case › Vibration-Induced Strain-Gauge Lead Wire Fracture

Vibration-Induced Strain-Gauge Lead Wire Fracture

E45-465 · Vibration and Mechanical Stress · Force Sensor · ★★

Problem Description

Vibration repeatedly bends the root of the strain-gauge lead wire until it fatigues and fractures; the bridge opens and there is no output

Root Cause

[Mechanism] The root of the lead wire is a stress concentration point; vibration bending propagates a fatigue crack there until it fractures and opens the bridge.
[Calculation] The bending stress at the root exceeds the fatigue limit, and the wire fractures after ten thousand cycles, leaving no output.
[Design Deficiency] The lead wire had no fixing, no slack, and no root protection.

Corrective Solution

① Root fixing: secure the lead wire with adhesive to protect the root → prevent bending
② Slack transition: leave slack in the lead wire to ease bending → reduce stress
③ Sleeve: add a protective sleeve at the root → protect the wire
④ Spot-weld reinforcement: spot-weld the lead wire → stabilize the connection
⑤ Regular inspection: check the lead wire for integrity → early correction
⑥ Open-circuit monitoring: monitor bridge continuity → early detection
⑦ Fracture verification: confirm by measuring the lead wire under vibration → data confirmation
⑧ Selection standardization: write lead-wire fixing into the process spec → control at the source

Checklist

Reference

GB/T 7551-2008 Load cells

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL