E45-355 · Environmental Protection and Temperature/Humidity · Temperature Sensor · ★★★
A temperature probe in a curing oven runs continuously for three months until its signal drops out; teardown shows the internal circuit has burned out and failed
[Mechanism] Long-term high temperature accelerates aging of electronic components; running above the rated temperature pushes the junction temperature past its limit and causes thermal breakdown.
[Calculation] The 150℃ inside the oven far exceeds the probe's 85℃ rating; at the rule of halving life for every 10℃, the life shrinks to 1/64 of the design value.
[Design Deficiency] The model was chosen for room temperature without calculating the actual temperature inside the oven, so the probe's temperature rating was insufficient.
① High-temperature selection: choose a probe rated to 180℃ → meet the oven's service condition
② Remote probe: insert the sensing end while keeping the circuit end outside the oven → keep the circuit clear of high temperature
③ Thermal break: add a ceramic insulating sleeve to block heat conduction → protect the circuit
④ Cold-junction compensation: extend the leads to move the transmitter circuit farther away → lower the junction temperature
⑤ Life calculation: derive the life from the junction temperature and choose a margin → avoid premature aging
⑥ Temperature monitoring: alarm when the circuit-end temperature exceeds 70℃ → overheating warning
⑦ High-temperature burn-in: run a 150℃ burn-in screen before shipment → reject weak parts
⑧ Selection standardization: write the oven's rated temperature into the mandatory selection criteria → control at the source
GB/T 2423.2-2008 Environmental testing for electric and electronic products - High temperature test