Knowledge Base › Electrical Sensor Error Case › Failure under Combined Strong Electromagnetic and High-Temperature Conditions

Failure under Combined Strong Electromagnetic and High-Temperature Conditions

E45-354 · Environmental Protection and Temperature/Humidity · Position Sensor · ★★

Problem Description

Beside an induction furnace, high temperature is combined with a strong magnetic field; the sensor fails both from over-temperature drift and from magnetic interference

Root Cause

[Mechanism] High temperature drifts the electronics while a strong alternating magnetic field induces interference; the two together produce an error far beyond either alone.
[Calculation] The 80℃ beside the furnace exceeds the rating, and magnetic-field induction adds mV-level interference; the combined error reaches 5%FS, more than the sum of the individual factors.
[Design Deficiency] The combined high-temperature and strong-magnetic-field condition was not evaluated, and the protection was single-purpose.

Corrective Solution

① Combined protection: choose an integrated 85℃-rated, magnetically shielded model → resist both factors at once
② Insulate and distance: add an insulating sleeve and keep the sensor away from the furnace → lower the temperature
③ Magnetic shielding: add a Permalloy shield can → attenuate the magnetic field
④ Differential immunity: use a differential signal to suppress common-mode magnetic pickup → reduce interference
⑤ Temperature and magnetic monitoring: alarm when the temperature or field exceeds limits → combined warning
⑥ Redundant checking: cross-check with two sensors → identify failure
⑦ Combined verification: run a combined high-temperature plus magnetic-field test to confirm → data confirmation
⑧ Selection standardization: write the combined condition into the mandatory selection criteria → control at the source

Checklist

Reference

GB/T 17626.8-2006 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test