E45-024 · Installation Position and Orientation · RTD Thermowell on a DN150 Main Steam Line · ★★★
The thermowell cantilever is 400mm long and resonates with an amplitude of 0.8mm; after 6 months it wears through, leaks and stops the steam
[Mechanism] The cantilever natural frequency approaches the vortex-shedding frequency and causes resonance; the alternating stress fatigues and wears the thermowell through.
[Calculation] Cantilever f_n = (1/2π)√(3EI/mL³) ≈45Hz and vortex shedding f_v = St·v/d ≈45Hz coincide, so resonance amplifies.
[Design Omission] No frequency check was made, the cantilever was not shortened, and fatigue was not verified.
① Shorten the cantilever: cut it to ≤200mm (from 400mm) to raise f_n → the long cantilever had a low f_n close to the shedding frequency and resonated; separate them
② Add support: add a support point or step down the diameter to change stiffness → a single cantilever is flexible; f_n>90Hz avoids resonance
③ Frequency separation: verify that f_n and vortex shedding f_v differ by ≥20%; coincidence causes amplification and is unsafe
④ Wear-resistant material: choose a wear-resistant thermowell (e.g., 316) → the original material was soft; use a wear-resistant one
⑤ Amplitude monitoring: set an amplitude monitor with a 0.2mm alarm threshold → resonance grows gradually; stop it early
⑥ Thickness check: measure wall thickness every six months for wear-through → fatigue is gradual; replace early
⑦ Modal test: run a modal test to verify f_n → design often skips it; confirm by measurement
⑧ Make it stick: write the cantilever frequency check into the thermowell design document → eliminates unchecked resonance at the source
GB/T 16839 Resistance thermometers