E45-365 · Environmental Protection and Temperature/Humidity · Proximity Sensor · ★★★
A small amount of water seeps into the cavity of a northern outdoor proximity switch; in winter it freezes and expands, bursting the housing and letting water in for permanent failure
[Mechanism] Water that has seeped into the cavity freezes at low temperature and expands by about 9%; the ice crystals press outward, cracking the housing and letting in a large amount of water.
[Calculation] Water expanding by 9% on freezing produces a bursting stress of tens of MPa, exceeding the plastic housing's strength and cracking it so water enters and shorts the circuit.
[Design Deficiency] The housing's sealing was inadequate and left a path for water seepage, and the frost-heave risk was never evaluated.
① Fully potted housing: epoxy-pot the entire cavity so there is no void → no water to freeze
② Better sealing: choose an IP68 fully sealed housing → prevent water seepage
③ Drainage to prevent accumulation: design the cavity so water cannot collect → no standing water
④ Cold-resistant housing: choose a housing material that does not embrittle at low temperature → resist frost cracking
⑤ Frost-safe placement: install away from spots that collect and freeze water → less exposure to freezing
⑥ Seal inspection: check the seal regularly for water seepage → early detection
⑦ Freeze-thaw verification: run a freeze-thaw cycle test to confirm → data confirmation
⑧ Selection standardization: write the outdoor frost-heave condition into the selection criteria → control at the source
GB/T 2423.1-2008 Environmental testing for electric and electronic products - Low temperature test