E45-363 · Environmental Protection and Temperature/Humidity · Pressure Sensor · ★★★
Next to a sterilization autoclave, a pressure transmitter is hit by direct high-temperature steam; the seal ring ages at high temperature and fails, letting steam into the cavity where it condenses and shorts the circuit
[Mechanism] High-temperature steam accelerates aging of the rubber seal ring, hardening it and robbing it of elasticity; steam seeps through the seal gap and condenses into water in the cavity.
[Calculation] Steam at 132℃ exceeds the seal ring's temperature rating; after aging its spring-back drops by 60% and the seal fails, and the condensed water in the cavity makes the insulation plummet.
[Design Deficiency] The seal ring material's temperature resistance was inadequate, and no steam barrier was provided.
① High-temperature seal: switch to a fluoroelastomer seal ring rated to 180℃ → resist aging
② Steam baffle: add a stainless-steel steam baffle to divert the direct blow → reduce the thermal shock
③ Remote transmitter: run a capillary from the pressure port → keep the circuit clear of steam
④ Condensate trap: add a condensate trap to block the steam → prevent ingress
⑤ Condensate drain design: provide drain holes in the cavity to remove collected water → prevent water buildup
⑥ Seal inspection: check the seal for aging regularly and replace it → maintain sealing
⑦ Steam verification: run a high-temperature steam endurance test to confirm → data confirmation
⑧ Selection standardization: write the direct-steam-blow condition into the selection criteria → control at the source
GB/T 2423.2-2008 Environmental testing for electric and electronic products - High temperature test