E45-362 · Environmental Protection and Temperature/Humidity · Displacement Sensor · ★★
At a desert photovoltaic plant, a displacement sensor is hit by both the day-night temperature swing and windblown sand; dust abrasion plus thermal drift make the accuracy plummet
[Mechanism] The large day-night temperature difference causes thermal drift, while windblown sand abrades the seal and the sensing face; the two together produce an error far beyond either alone.
[Calculation] A desert day-night temperature difference of 50℃ causes 0.8% drift; combined with dust abrasion of the seal letting sand in, the total reaches a 2%FS out-of-tolerance.
[Design Deficiency] The combined temperature-swing and dust condition was not evaluated, and the protection and thermal compensation were single-purpose.
① Combined protection: choose an IP67 dust-proof, wide-temperature model → resist both factors at once
② Labyrinth seal: add a labyrinth dust seal at the sensing face → block windblown sand
③ Temperature compensation: use a built-in compensation algorithm to correct the day-night drift → reduce thermal drift
④ Sunshade: add a sunshade to narrow the temperature difference → reduce expansion and contraction
⑤ Wear-resistant surface: coat the sensing face with a hard wear-resistant layer → resist abrasion
⑥ Temperature and dust monitoring: alarm when temperature or blockage exceeds limits → combined warning
⑦ Combined verification: run a combined temperature-variation plus sand-dust test to confirm → data confirmation
⑧ Selection standardization: write the desert combined condition into the selection criteria → control at the source
GB/T 2423.37-2006 Environmental testing for electric and electronic products - Dust test