E45-018 · Installation Position and Orientation · Accelerometer on a Motor Bearing Housing · ★
Mounted on a 2mm sheet-steel bracket, the 10kHz amplitude is 40% lower than with rigid mounting, so early faults are missed
[Mechanism] A bracket with high compliance resonates and absorbs high-frequency energy; the transmissibility drops below 1 and the measured vibration is underestimated.
[Calculation] The bracket natural frequency f_n ≈800Hz is close to the measured 1kHz; transmissibility T = 1/√((1−(f/f_n)²)²) = 0.6, a 40% attenuation.
[Design Omission] Bracket stiffness was not checked, no rigid measuring point was chosen, and no frequency-response verification was made.
① Rigid surface: remount on a rigid machined surface of the bearing housing (was a 2mm sheet) → a rigid body transmits vibration faithfully, removing the 40% high-frequency attenuation caused by compliance
② Bracket stiffness: increase the thickness to ≥6mm or add ribs → a thin plate has a low f_n near the measured frequency; f_n>3kHz avoids resonance
③ Mounting method: use a magnetic base or insulated bolts to fasten directly to the machine body → adhesive loosens easily; fasten securely
④ Frequency-response check: run a frequency-response function check from 50Hz to 10kHz → the transmissibility is not flat; make the whole band trustworthy
⑤ Lightweight: choose a light sensor with mass <1/10 of the measured point → added mass changes the mode; do not disturb it
⑥ Looseness check: check the bracket for looseness monthly → vibration loosens it; correct it early
⑦ Hammer test: run a hammer test to check f_n>3kHz → design often skips it; confirm by measurement
⑧ Make it stick: write the bracket stiffness requirement into the measuring-point layout card → eliminates unaccounted attenuation at the source
GB/T 11348 Mechanical vibration of rotating machinery