Knowledge Base › Electrical Sensor Error Case › Encoder Not Coaxial with the Load Shaft Causes Pulse Jitter and Accumulated Error

Encoder Not Coaxial with the Load Shaft Causes Pulse Jitter and Accumulated Error

E45-019 · Installation Position and Orientation · Incremental Encoder on a Winder Spindle · ★★

Problem Description

Radial runout of 0.3mm; pulses per revolution fluctuate ±15, and the length error accumulates 0.5%/100m

Root Cause

[Mechanism] Eccentricity subjects the encoder disk to a cyclic alternating radial force; zero-point jitter makes the pulse count unstable.
[Calculation] Eccentricity e = 0.3mm, shaft radius R = 20mm, angular error Δθ = 2e/R = 3%, pulse jitter ±15/1000.
[Design Omission] No coaxial alignment was done, no flexible coupling was used, and no travel comparison was made.

Corrective Solution

① Coaxial alignment: control radial runout from 0.3mm to ≤0.05mm → by Δθ = 2e/R (R = 20mm) the angular error drops from 3% to 0.5% and the per-revolution pulse jitter narrows from ±15/1000 to within ±2
② Flexible coupling: add a flexible coupling to compensate residual micro-eccentricity (allows ±0.2mm misalignment) → absorbs the remaining alignment error and avoids transmitting shaft offset rigidly to the encoder disk
③ Alignment sleeve: fit a precision alignment sleeve on the shaft end and dial-indicate to recheck concentricity → removes the eccentricity from flange-face machining error and ensures true concentricity
④ Count comparison: compare full-revolution pulses against a reference rotary table (error ≤1 in 1000 pulses) → a jitter of ±15 makes the count out of tolerance, showing the alignment is not yet right
⑤ Wound-length comparison: use a laser length meter to hold the length error below <0.1% → corrects the original 0.5%/100m accumulated drift and calibrates the true factor
⑥ Redundant cross-check: use two high-resolution encoder signals for a redundant cross-check → when one channel jitters the other verifies it, identifying a failed channel and preventing miscounts
⑦ Wear check: inspect the coupling's rubber element monthly for wear → wear reintroduces eccentricity; replace early to maintain compensation
⑧ Make it stick: put concentricity ≤0.05mm into the drive assembly work card as a mandatory check → eliminates skipped alignment at the source

Checklist

Reference

GB/T 29298 Encoders

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL