E45-346 · Environmental Protection and Temperature/Humidity · Displacement Sensor · ★★
The bracket beside the furnace expands under radiant heat; the sensor mounting position shifts and the measurement datum drifts
[Mechanism] Radiant heat from the furnace expands and lengthens the steel bracket; the sensor moves with the bracket, and the measurement datum shifts, producing a systematic error.
[Calculation] A 500mm steel bracket heated by 100℃ expands 0.6mm, which appears directly as a 0.6mm systematic deviation in the displacement measurement.
[Design Omission] The bracket had no thermal insulation or thermal compensation.
① Insulated bracket: add insulating pads to the bracket → cut off radiant-heat conduction
② Heat shield: add a reflective heat shield on the furnace side → reduce radiant heating
③ Low-expansion material: choose a low-expansion material such as Invar for the bracket → reduce thermal deformation
④ Datum compensation: add a reference-datum probe to compensate the displacement → cancel the drift
⑤ Cooled bracket: pass cooling water through the bracket → control temperature
⑥ Temperature monitoring: alarm when the bracket temperature exceeds the limit → thermal-deformation warning
⑦ Thermal-deformation verification: heat up and measure the datum displacement to confirm → data verification
⑧ Selection standardization: write radiant-heat duty insulation requirements into the installation card → control at the source
GB/T 2423.2-2008 Environmental testing for electric and electronic products - High temperature test