MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Electrical Sensor Error Case › Seawater Immersion Electrochemical Corrosion Causes a Short

Seawater Immersion Electrochemical Corrosion Causes a Short

E45-345 · Environmental Protection and Temperature/Humidity · Underwater Level Sensor · ★★★

Problem Description

A dock underwater sensor immersed in seawater for a long time: crevice electrochemical corrosion of the stainless-steel housing perforates it, letting water in and shorting it

Root Cause

[Mechanism] Chloride ions in seawater cause crevice corrosion at the gaps in the stainless steel; once the passive film breaks down, the local potential difference accelerates pitting until perforation.
[Calculation] Seawater chloride is about 19g/L; 316L corrodes at roughly 0.05mm/month in the crevice, so in half a year 0.3mm penetrates the thin-wall seal.
[Design Omission] The material's corrosion-resistance grade was insufficient, with no crevice-corrosion protection.

Corrective Solution

① Material upgrade: for seawater immersion → choose titanium alloy or duplex steel → resist chloride crevice corrosion
② Seamless construction: weld into one piece to eliminate gaps → no crevice-corrosion sites
③ Cathodic protection: add sacrificial anode blocks → electrochemically protect the body
④ Coating isolation: apply a seawater-resistant coating to the housing → isolate contact
⑤ Upgraded sealing: multiple O-rings plus potting → prevent seepage
⑥ Corrosion monitoring: periodically measure wall thickness, warn when <0.8mm → replace before perforation
⑦ Immersion verification: run a seawater immersion test for ≥6 months without perforation → data confirmation
⑧ Selection standardization: write seawater-environment materials into the selection table → control at the source

Checklist

Reference

GB/T 10125-2021 Corrosion tests in artificial atmospheres - Salt spray tests