E45-118 · Signal Interference and EMC · Magnetostrictive Displacement Sensor · ★★
A nearby strong-magnet device makes the magnetostrictive displacement reading jump erratically by ±2mm
[Mechanism] An external strong magnetic field superimposes on the bias field of the magnetostrictive waveguide wire, disturbing the propagation of the torsion wave and corrupting the timing.
[Calculation] An external magnetic field B≈10mT superimposes on the bias, slightly changing the wave velocity; the timing error corresponds to jumps of ±2mm.
[Design Omission] The sensor was not magnetically shielded, not kept away from strong magnets and not filtered.
① Magnetic shielding: fit the sensor with a permalloy tube → attenuates the external field by 20dB, jumps go to zero
② Move away from strong magnets: keep at least 0.5m from strong-magnet equipment → reduces B
③ Shielded twisted pair: run the signal cable as shielded twisted pair → suppresses coupling
④ Low-pass filtering: add a low-pass filter → filters out the interference
⑤ Isolation: isolate the signal → cuts common mode
⑥ Calibration: compare against a standard rule on site (difference ≤0.1mm) → correct the bias
⑦ Verify by measurement: readings under strong-magnet conditions (jumps ≤0.2mm) → confirmed
⑧ Institutionalize: write keeping the magnetostrictive sensor away from strong magnets into the standard → gate at the source
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test