E45-436 · Vibration and Mechanical Stress · Acceleration Sensor · ★★★
The equipment ran in the resonance region for a long time; fatigue cracks in the sensor mounting arm propagated, posing a fracture risk
[Mechanism] Long-term resonance drives the alternating stress beyond the fatigue limit; a crack initiates and grows to a critical size, posing a fracture risk.
[Calculation] The resonance stress amplitude exceeds the material's fatigue limit; after a thousand hours of operation the crack grows to a dangerous size.
[Design Deficiency] Resonance was not avoided and no fatigue strength check was made.
① Avoid resonance: shift the natural frequency away from the excitation → prevent fatigue
② Reduce stress: optimize the structure to lower the stress amplitude → extend life
③ Damping: add damping to dissipate energy → reduce the amplitude
④ Fatigue check: verify the life against the S-N curve → ensure safety
⑤ NDT monitoring: periodic non-destructive testing for cracks → early detection
⑥ Restricted operation: limit the operating time in the resonance region → slow the propagation
⑦ Fatigue verification: confirm with a vibration endurance test → data confirmation
⑧ Selection standardization: write fatigue life into the design items → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test