E45-348 · Environmental Protection and Temperature/Humidity · Pressure Transmitter · ★★
The equipment starts and stops frequently, alternating hot and cold; the air in the cavity expands and contracts, breathing in outside moisture that condenses
[Mechanism] Rising and falling temperature make the gas in the cavity expand and contract; on cooling a negative pressure forms and draws outside moist air in through the gaps, and repeated breathing accumulates moisture that condenses.
[Calculation] A 40℃ change in cavity temperature alters the gas volume by about 13%; each cooling cycle draws in an equal volume of moist air, and after many cycles the accumulated moisture reaches condensation.
[Design Omission] The sealed cavity had no breathing/pressure-balance provision, so it breathes in moisture.
① Pressure balance: add a waterproof breathable membrane (Gore) → pressure equalizes without drawing in moisture
② Desiccant: place replaceable desiccant in the cavity → absorb accumulated moisture
③ Potting against moisture: pot the circuit → it will not leak current even after moisture ingress
④ Slight constant heating: add a small heater to keep the cavity above the dew point → suppress condensation
⑤ Upgraded sealing: reduce breathing gaps → lower the amount drawn in
⑥ Insulation monitoring: alarm when <10MΩ → detect moisture ingress early
⑦ Thermal-cycling verification: run a thermal-cycle humidity test to confirm → data confirmation
⑧ Selection standardization: write breathing design for alternating hot/cold duty into the spec → control at the source
GB/T 2423.22-2012 Environmental testing for electric and electronic products - Test for temperature change