E45-352 · Environmental Protection and Temperature/Humidity · Through-Beam Sensor · ★★
In a machining shop, oil mist deposits on the lens as a film; the optical path is attenuated, shortening the detection distance and causing misjudgment
[Mechanism] Cutting-oil mist condenses on the lens surface into an oil film; the film scatters and absorbs light, lowering the effective luminous flux, shortening the detection distance, and causing intermittent misjudgment.
[Calculation] The oil film cuts infrared transmission by about 50%; the weakened received signal shrinks the detection distance to 0.5 times, and the insufficient signal-to-noise ratio causes misjudgment.
[Design Omission] No oil-mist protection or cleaning measures were provided.
① Oil-resistant window: fit the lens with an oleophobic-coated window → oil adheres less readily
② Air-curtain purge: a positive-pressure air curtain in front of the lens → blocks oil mist from contact
③ Sealed protection: add an oil-guard shroud to the sensor → isolates the oil mist
④ Distance margin: select with a ×0.5 derating for oil-film attenuation → leave headroom
⑤ Regular cleaning: wipe the lens periodically to remove oil → keep transmission
⑥ Signal monitoring: warn on low received intensity → detect fouling early
⑦ Oil-mist verification: run an oil-mist environment test to confirm → data confirmation
⑧ Selection standardization: write oil-mist duty protection into the selection spec → control at the source
GB/T 4208-2017 Degrees of protection provided by enclosures (IP code)