E45-059 · Cables and Drag Chains · Low-Coverage Shielded Cable · ★★
The shield's braid coverage is only 50%, so high-frequency shielding effectiveness is insufficient at 30dB, and radiation from a nearby phone makes the reading jump occasionally
[Mechanism] Low braid coverage lets high-frequency electromagnetic fields leak through the mesh openings, and shielding effectiveness falls as the coverage drops.
[Calculation] At 50% coverage the high-frequency (>100MHz) shielding effectiveness is only ≈30dB, far below the ≥60dB requirement, so leakage causes interference.
[Design Omission] Coverage was not selected for the frequency, and shielding effectiveness was never measured.
① Raise coverage: switch to braid coverage ≥85% or add a double aluminum-foil shield → effectiveness ≥60dB
② Dual shield: combine braid and aluminum foil → shields at high frequency as well
③ Effectiveness test: measure shielding effectiveness after installation (≥60dB) → confirm by measurement
④ Institutionalize: make coverage a mandatory item in the selection table → gatekeeping at the source
⑤ Routing: keep away from radiation sources → less shielding needed
⑥ Termination: terminate the shield with a 360° bond → no gaps
⑦ EMC test: run a radiated-immunity test → confirm by measurement
⑧ Maintenance: add to the EMC check card → inspect periodically
GB/T 18268.3-2010 EMC requirements for measurement and control equipment