E45-076 · Signal Interference and EMC · Absolute Encoder · ★★
During welding in the workshop the encoder loses pulses (8~15 lost per weld) and positioning deviates by up to ±2mm; normal operation should lose none
[Mechanism] The welding machine's arc strike produces a kV-level voltage spike and a strong magnetic-field pulse that couple through space radiation into the long encoder cable, superimposing on the A/B phases so the edges are misjudged and pulses are lost.
[Calculation] With arc-strike voltage ≈60V, arc discharge di/dt≈1kA/ms and magnetic field at 2m B=μ0·I/2πr≈1e-4T, the induced e≈B·L·v>1V in a 20cm signal loop exceeds the 0.4V logic threshold and causes false triggering.
[Design Omission] The encoder cable was not shielded, not kept away from the welding area, had no ferrite beads, and did not use differential long-line drive.
① Route away: keep the encoder cable ≥3m from the welding point or run it in metal conduit → avoids radiation, and pulse loss drops from 8~15 per weld to 0
② Shielding and twisted pair: switch to shielded twisted pair with the shield 360° terminated at both ends → suppresses radiated coupling
③ Add ferrite beads: fit ferrite beads at both ends of the signal cable (impedance ≥100Ω@100MHz) → absorbs spikes and drives false triggering to zero
④ Differential drive: switch to RS485 differential long-line transceivers → common-mode rejection ratio ≥80dB
⑤ Welder isolation: add RC snubbers and a shielded enclosure to the welder → reduces radiation at the source
⑥ Signal filtering: add a TVS and a low-pass filter at the signal end (cutoff 10MHz) → clips spikes
⑦ Verification by test: count comparison under welding conditions (difference 0) → confirm no loss
⑧ Institutionalize: write the encoder-cable EMC routing into the assembly card → gatekeeping at the source
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test