Knowledge Base › Electrical Sensor Error Case › Combined Mildew and Drift Under High Temperature and Humidity

Combined Mildew and Drift Under High Temperature and Humidity

E45-374 · Environmental Protection and Temperature/Humidity · Humidity Sensor · ★★★

Problem Description

In a tropical storeroom with high temperature and humidity, the humidity probe suffers both mildew contamination and thermal drift; readings stay high and inaccurate over the long term

Root Cause

[Mechanism] High temperature accelerates drift and high humidity promotes mildew growth that contaminates the sensing film; together the two factors produce an error far larger than either alone.
[Calculation] Storeroom conditions of 35℃/90%RH cause mildew on the sensing film plus thermal drift, keeping the humidity reading persistently 6%RH high, beyond tolerance.
[Design Deficiency] The combined high-temperature/high-humidity condition was not evaluated, and protection and temperature compensation addressed only one factor each.

Corrective Solution

① Combined protection: choose anti-mildew wide-temperature/humidity probes → withstand both factors
② Anti-mildew filter cap: add an anti-mildew hydrophobic sintered cap over the sensing film → block microbial contamination
③ Temperature compensation: build in temperature compensation to correct thermal drift → less thermal drift
④ Conformal coating: apply conformal coating to the circuit for mildew and moisture resistance → protect the circuit
⑤ Periodic replacement: replace and recalibrate the sensing element regularly → keep accuracy
⑥ Temperature/humidity monitoring: alarm on temperature/humidity limit violations and contamination → combined early warning
⑦ Combined verification: run high-temperature/high-humidity plus mildew tests → data confirmation
⑧ Selection standardization: write the combined high-temperature/high-humidity condition into the selection criteria → control at the source

Checklist

Reference

GB/T 2423.4-2008 Environmental testing for electric and electronic products - Damp heat, cyclic test