Problem Description

In extreme cold outdoors, the grease in a mechanical displacement sensor solidifies and thickens, raising the resistance to probe movement and causing lagging, distorted response

Root Cause

[Mechanism] Ordinary grease rises sharply in viscosity and even solidifies at low temperature, so resistance to movement of the mechanical probe increases and tracking lags.
[Calculation] At -30℃ ordinary grease rises to a hundred times its room-temperature viscosity; probe response time grows from 50 ms to 800 ms and the response becomes dynamically distorted.
[Design Deficiency] The grease's low-temperature grade was insufficient, and the mechanism was not adapted for low temperature.

Corrective Solution

① Low-temperature grease: switch to grease rated to -50℃ → maintain flow
② Non-contact type: switch to a non-contact inductive type → no mechanical resistance
③ Heating and insulation: add micro-heating and insulation to the mechanism → prevent solidification
④ Material matching: choose materials with stable low-temperature friction for the kinematic pair → less resistance
⑤ Cold insulation: add an insulating cover to reduce the low-temperature effect → slow solidification
⑥ Response monitoring: alarm when dynamic response exceeds limits → early detection
⑦ Low-temperature verification: run a -40℃ low-temperature motion test → data confirmation
⑧ Selection standardization: write the extreme-cold condition into the selection criteria → control at the source

Checklist

Reference

GB/T 2423.1-2008 Environmental testing for electric and electronic products - Low temperature test