E45-184 · Grounding and Shielding · Outdoor Transmitter · ★★★
After a direct lightning strike, signal modules fail in batches; the lightning grounding electrode is shared with the signal ground, causing back-flash
[Mechanism] When the lightning grounding electrode discharges a large current its potential rises sharply; if it is shared with or near the signal ground (equipment ground), the high potential couples through the ground grid and back-flashes to the device ports; a shared ground lets the lightning current pour straight into the signal circuit.
[Calculation] A lightning current of 10kA into an electrode with R=5Ω → electrode potential 50kV; with the signal ground 2m away and a soil resistivity of 100Ω·m the coupled potential still reaches the kV level, far beyond the port withstand voltage.
[Design Omission] There is no zoning and equipotential coordination among the lightning ground, protective earth, and signal ground.
① Separate electrode spacing: keep the lightning grounding electrode ≥20m from the signal ground or isolate them → lowers coupling
② Equipotential coordination: when close together, use an isolating device to coordinate the potentials → no direct back-flash
③ Multi-stage SPD: fit a first stage (20kA) plus a second stage (10kA) SPD at the port entry → staged clamping
④ Signal isolation: add optical/magnetic isolation (1500V) at the front end → the lightning current cannot pour in
⑤ Shielded down-lead: run the signal cable in metal conduit bonded to PE nearby → diverts the current
⑥ Residual-voltage test: SPD residual voltage ≤ device withstand voltage → verify protection
⑦ Post-strike check: measure module insulation after each storm → find damage in time
⑧ Write the lightning-protection zoning into the lightning design → gate at the source
GB 50057-2010 Design code for protection of structures against lightning