Knowledge Base › Electrical Sensor Error Case › Electrostatic Shield Not Bonded to the Chassis, Field Leakage

Electrostatic Shield Not Bonded to the Chassis, Field Leakage

E45-185 · Grounding and Shielding · Capacitive Proximity Switch · ★

Problem Description

A nearby live part makes the proximity switch trip falsely; opening the case reveals the internal shield is left floating, not bonded to the chassis

Root Cause

[Mechanism] An electrostatic shield relies on a conductor to terminate the external field lines at the shield and conduct them to ground; if the shield is not bonded to the chassis (ground), the external field still couples to the sensitive internal circuit, inducing charge and causing false actuation.
[Calculation] External field E=5kV/m with a coupling capacitance C=2pF when unshielded → a ΔU=10V corresponding to the false-trip threshold is reached and triggers; once bonded to the chassis the field terminates at the chassis.
[Design Omission] The sensitive parts inside the metal case are not at the same potential as the case, and the shield is left floating.

Corrective Solution

① Shield to chassis: bring the internal shield into 360° contact with the chassis through a conductive gasket → the external field terminates at the chassis
② Conductive gasket: use beryllium-copper spring fingers at the seams for electrical continuity → no field leakage
③ Chassis grounding: bond the case to PE → the shield has a reference ground
④ Equipotential: bond the internal circuit ground to the case through a capacitor (10nF) → bleeds static charge without admitting mains frequency
⑤ Seam control: keep the closed-case seam <λ/20 (λ=3m at 100MHz) → continuous shielding
⑥ False-trip test: re-test near a live part with no false actuation → verify
⑦ Shielding effectiveness: apply electrostatic discharge (±8kV) with no false actuation → verify
⑧ Write the shield grounding into the structural EMC specification → gate at the source

Checklist

Reference

GB/T 17626.2-2018 Electrostatic discharge immunity test