Knowledge Base › Electrical Sensor Error Case › Poor 360° Shield Bonding at the Connector Causes EMC Radiation to Exceed Limits

Poor 360° Shield Bonding at the Connector Causes EMC Radiation to Exceed Limits

E45-036 · Cables and Drag Chains · Servo Motor Connector Shield · ★★★

Problem Description

At the connector the shield makes only point contact instead of a 360° bond; the EMC test shows radiation exceeding the limit by 6dB, and a nearby sensor is disturbed and its reading jitters

Root Cause

[Mechanism] The shield and the connector housing are not continuously bonded, forming a gap; high-frequency signals leak and radiate through the gap, and external fields couple into the line through it.
[Calculation] With a gap length l≈10mm and a wavelength λ=3m (100MHz), l/λ=0.003; the gap lowers shielding effectiveness by about 20dB and the radiation exceeds the limit.
[Design Omission] No 360° shield ring was used, and bonding continuity was not tested.

Corrective Solution

① 360° bonding: use a shield ring (EMC clamp) at the connector to bond the shield to the housing 360° → gap eliminated, radiation within limits
② Shield ring: choose a spring-finger shield ring → continuous rather than point contact
③ Bonding test: measure the bonding impedance after installation (<10mΩ) → confirms continuity
④ Institutionalize: make the 360° bond a mandatory item in the wiring diagram → drawing gatekeeping
⑤ EMC test: perform a radiated emission test (≤ limit) → confirm compliance by measurement
⑥ Housing: give the connector housing a conductive metal oxide treatment → keeps good contact
⑦ Routing: keep sensitive lines away from interference sources → less coupling
⑧ Maintenance: add to the EMC check card → inspect periodically

Checklist

Reference

GB/T 17626.3-2006 EMC testing