E45-458 · Vibration and Mechanical Stress · Communication Module · ★★
Vibration breaks strands in the shielding braid of the communication cable; poor grounding increases interference and causes bit errors
[Mechanism] Vibration bends the shielding braid alternately until it fatigues and breaks strands; the shielding coverage drops, its effectiveness falls and interference enters.
[Calculation] Broken shield strands reduce the coverage from 90% to 60%; interference coupling rises and the bit-error rate increases.
[Design Deficiency] The shield was not reinforced and the bend radius was insufficient.
① Add a sleeve: fit a corrugated tube over the wear point → protect the shield
② Bend allowance: keep the bend radius ≥ 10× the diameter → reduce fatigue
③ Foil shielding: use aluminum foil plus braid as a double layer → preserve coverage
④ Fixing and damping: secure the cable reliably → reduce wear
⑤ Coverage inspection: inspect the shield for integrity → early correction
⑥ Interference monitoring: monitor the bit-error rate → early detection
⑦ Strand-break verification: confirm by measuring the shield under vibration → data confirmation
⑧ Selection standardization: write shield protection into the wiring spec → control at the source
GB/T 5013.1-2008 Rubber insulated cables of rated voltages 450-750 V